Barracuda Backup

How to Resolve "Error opening object"

  • Last updated on

If the Barracuda Backup Report displays the message "Error opening object", use the following steps to clear the warning:

  1. Verify that your antivirus software has not quarantined your files; quarantined files are locked and cannot be backed up. Remove the files from the antivirus software quarantine.
  2. If you do not find quarantined files, verify the file exists. If the file does exist, verify no other backup agent is running at the same time as the Barracuda Backup appliance backup process.
  3. Review the Backup Agent logs. Open the bbtrace.txt file, usually found here: C:\Program Files\Barracuda\Barracuda Backup Agent\log. Review the file for errors and cross reference the timestamp with both Application and System window event logs.