It seems like your browser didn't download the required fonts. Please revise your security settings and try again.
Barracuda CloudGen Firewall

F900 Revision C

  • Last updated on
F900 Rev. C Model CCC (32x1 GbE RJ45 Ethernet network ports)
F900b.CCC_FrontRack.png

F900 Rev. C Model CCE (16x1 GbE RJ45 Ethernet + 8x10 GbE SFP + (glass fiber) network ports)
F900b.CCE_FrontRack.png

F900 Rev. C Model CFE (8x1 GbE + 8x1 GbE SFP (glass fiber) + 8x10 GbE SFP+ (glass fiber) network ports)
F900b.CFE_FrontRack.png

F900 Rev. C Model CFEQ (8x1 GbE + 8x1 GbE SFP (glass fiber) + 4x10 GbE SFP+ (glass fiber) network ports + 2x40 GbE QSFP+ (glass fiber) network ports)
F900b.CFEQ_FrontRack.png

Power Supply Unit for all Upper Models

psu_F800_F900.png

Supported Barracuda Network Module Combinations

Default Port Configuration

Port Label

OS Notation

Speed/Type

Management Port

MGMT

MGMT

10/100/1000 MBit RJ45

X

IPMI

IPMI

10/100/1000 MBit RJ45

X

The CloudGen Firewall hardware appliances ship with a Quick Start Guide. Follow this guide to connect to your firewall. To protect your network, follow the instructions for the standard deployment.

 Hardware Specifications

Warranty and Safety Instructions

Opening your Barracuda Networks appliance or removing its warranty label unless instructed to do so by Barracuda Networks support will void your warranty and hardware support. Barracuda Networks Appliance Safety Instructions

Interface

Model CCC

  • 32x 1 GbE RJ45 Ethernet

Model CCE

  • 16x 1 GbE RJ45 Ethernet

  • 8x 10 GbE SFP+

Model CFE

  • 8x  1 GbE RJ45 Ethernet

  • 8x  1 GbE SFP

  • 8x 10 GbE SFP+

Model CFEQ

  • 8x 1 GbE RJ45 Ethernet

  • 8x 1 GbE SFP

  • 4x 10 GbE SFP+

  • 2x 40 GbE QSFP+

USB 2.0

2

Serial console

1 [RJ45]

IPMI

1 [RJ45]

System

CPU

Intel Xeon 32 cores

RAM [GB]

64

Mass Storage

Type

SSD

Size [GB]

430 or higher

Size, Weight, Dimensions

Appliance weight [lbs]

24

Appliance weight [kg]

10.9

Carton weight with appliance [lbs]

42

Carton weight with appliance [kg]

19

Appliance size: width x depth x height [in]

17.2 x 21.625 x 1.7

Appliance size: width x depth x height [mm]

440 x 550 x 44

Carton size: width x depth x height [in]

22.5 x 30.25 x 9

Carton size: width x depth x height [mm]

572 x 770 x 229

Form factor

1U Rack Mount

Hardware

Display

Yes

Cooling

Fans

Power supply

Dual hot swap, internal

Environmental

Noise emission [average db/A] in idle mode,
30% fan duty at 25 [°C] ambient temperature

45.3

Noise emission [average db/A] in full loading mode,
60% fan duty at 25 [°C] ambient temperature

62.6

Noise emission [average db/A] in full loading mode,
60% fan duty at 40 [°C] ambient temperature

73.9

Operating temperature [°F]

+32 to +104

Operating temperature [°C]

0 to +40

Storage temperature [°F]

-4 to +167

Storage temperature [°C]

-20 to +75

Operating humidity (non-condensing)

10% to 85%

Certifications & Compliance

CE emissions

Yes

CE electrical safety

Yes

FCC emissions

Yes

MTBF [system]

MTBF [yrs.]

>7

Power & Efficiency

Power supply

Dual hot swap

Power supply type

Internal

Power type [AC/DC]

AC

Input rating [Volts]

100-240

Input frequency [Hz]

50-60

Auto sense

Yes

Wattage / max. power draw [W]

550

Max. power draw (@ 120V) [A]

7

Max. power draw (@ 230V) [A]

3.5

Estimated power consumption [W]

322

CPU’s TDP [W]

135

Max. heat dissipation [W]

~330

Max. heat dissipation [BTU]

~1.124

Energy efficiency [average]

> 88%

The hardware specifications list was valid at the time this manual was published. The listed components are subject to change at any time, as Barracuda Networks may change hardware components due to technological advancements. Therefore, the list may not reflect the current hardware configuration of the Barracuda Networks CloudGen Firewall or Control Center appliance it was delivered with.

Known Issues

  • The system recovery will not work correctly with firmware 9.0.3. [BNNGF-95642]

  • After shutting down the appliances with the command ‘shutdown -h’, the display will stay on and the fans continue running. As a workaround, physically disconnect the appliance from the power supply. [BNNGF-95643]

  • LED and buzzer do not function during the installation process.

LEDs and Acoustic Signals

Your appliance is equipped with a variety of LEDs. One of them is the Status LED. It is labeled either with a heart symbol or the term 'Status'. It indicates the appliance’s operational state by changing colors between green and red and by changing between blinking and steady glowing. The tables below show the different meanings of the different glowing states and acoustic signals:

LED Color

Status

Meaning Installation

Meaning Operation

All LEDs Off

Off

Appliance is powered off or installation has not initialized far enough for LED control when installation is started.

Appliance is powered off.

Power LED front side - GREEN

Steady

Installation was completed successfully, appliance is halted for reboot or installation was not yet initialized far enough for LED control.

Appliance is plugged in and is on.

Status LED front side - GREEN/RED

Off

Installation has not initialized far enough for LED control when installation is started.

-

Status LED front side - GREEN

Steady

Installation was completed successfully, appliance is halted for reboot.

Appliance is up and running.

Status LED front side - GREEN

Blinking

Normal installation.

Appliance is either booting, shutting down, or performing a system update.

Status LED front side - RED

Steady

-

Appliance is halted and may be disconnected.

Status LED front side - RED

Blinking

Error during installation.

An error has appeared preventing the appliance from entering the up state.

Status LED front side - RED/GREEN

Steady

-

Appliance is in ART mode.

Disc LED front side - YELLOW

Blinking

Appliance is reading or writing on storage.

Appliance is accessing the internal storage.

Port LEDs - GREEN/YELLOW

Left blinking

Data transfer – Yellow (10/100 Mbps)

Port in use.

Right steady

-

Port is on.

PSU LEDs - GREEN

Steady

PSU modules connected and running

Power supply unit is up and running.

Off

Power defective, standby, or shutdown

Power supply unit is off or in standby mode.

Acoustic Signal

Frequency

Meaning Installation

Beep

1 time

Unit starts booting

Beep

3 times

Installation is completed successfully and appliance is halted for reboot. After reboot, one beep indicates booting.

Not all appliances support yellow and/or red LED colors. Depending on the appliance type, the status LED might be on by default and it might take some time during boot and installation to start either blinking or changing the color. Furthermore, the status LED might blink at different frequencies.

Serial Console Port

In order to establish a console connection to the appliance using a serial cable (Revision A: DB9, Revision B: RJ45), you need to configure the serial port on the terminal using the following parameters:

Parameter

Value

Baud

19200

Bits

8

Stop bit

1

Parity

None

Handshake

None

LC Display

Navigating

This security appliance features a key pad with four keys and an LCD panel on the left side of the front panel. These may be used to obtain certain information and to perform certain commands directly on the appliance.

Keyboard Button

Command

Left arrow

Navigates back or acts like an Escape key while working in the LCD menu.

Up arrow

Navigates up or increases a value.

Down arrow

Navigates down or decreases a value.

Right arrow

Navigates forth or acts like an Enter key for confirming a configuration step.

OK

Confirm

LCD Display Menu

You may use the LCD display and the keypad to access certain appliance features. Use the up and down keys to navigate through the items of the main menu.

The LCD menu features the following items from top to bottom:

LCD Menu

Meaning

Appliance type, OS version and release number

This is the default display.

IP address and subnet mask

Shows the configured IP address and subnet mask of the appliance.

Time and date

Shows time and date currently configured on the appliance.

Uptime of Barracuda OS

The uptime in days, hours and minutes.

Serial number of the appliance

Unique identifier for the appliance.

Shutdown menu

Enables you to shut down the appliance.

Reboot menu

Enables you to reboot the appliance.

Menu to change the management IP address

Configure the IP address for the management port.

Menu to boot into ART during the next reboot

Enables you to set a flag that will cause the appliance to boot into ART the next time it is rebooted.
Once set, this flag can not be deleted through the menu. When rebooted, the appliance will not start Barracuda OS, but ART instead. You may connect to the appliance by using the serial console or by SSH. A managed F-Series Firewall running in ART mode cannot be managed through the Control Center, although it will connect to the Control Center to signal its presence.

Rack Mounting

For information on how to mount your appliance, see Rack Installation for Barracuda CloudGen Firewall and Barracuda CloudGen WAN.