It seems like your browser didn't download the required fonts. Please revise your security settings and try again.

Barracuda Message Archiver Hardware Specifications

  • Last updated on

The information in this article are based on current hardware models, however, models differ based on release date and may change in the future. If your appliance specifications differ from those shown in this article, contact Barracuda Networks Technical Support  for additional information.

Barracuda Message Archiver Form Factor

Model

Form Factor
(Prior to November 2014)

Form Factor
(November 2014 and Later)

150

Rack mountable - 1U

Rack mountable - 1U

350

Rack mountable - 1U

Rack mountable - 1U

450

Rack mountable - 1U

Rack mountable - 1U

650

Rack mountable - 1U

Rack mountable - 1U

850

Rack mountable - 2U

Rack mountable - 2U

950

Rack mountable - 2U

Rack mountable - 3U

1050

Rack mountable - 3U

Rack mountable - 4U

Barracuda Message Archiver Weight and Dimensions

Model

Weight in Pounds

Dimensions in Inches (D x W x H) 

150

11

10.5 x 17.2 x 1.75

350

33

20 x 17.2 x 1.75

450

33

20 x 17.2 x 1.75

650

33

20 x 17.2 x 1.75

850

75

25.5 x 17.2 x 3.5

950

66

25.5 x 17.2 x 5.25

1050

108

27.5 x 17.2 x 7

Barracuda Message Archiver Disk Arrangement and Redundancy Disk Array (RAID)

Model

Disk Arrangement

Redundancy Disk Array (RAID)

650

4 x 6 TB

SW RAID 10

850

4 x 12 TB

SW RAID 10

950

8 x 6 TB

HW RAID 6

1050

20 x 6 TB

HW RAID 60

Barracuda Message Archiver Network Interface Card

The Barracuda Message Archiver model 650 and higher contains two network interface cards (NICs) that you can place on separate networks to increase bandwidth. Note that you cannot team, that is, add, the NICs together.

Model

Number of Interfaces

150

1

350

1

450

1

650

2

850

2

950

2

1050

2

10 Gigabit Ethernet Card Standard

Models 650/850/950/1050 include a 10 Gigabit Ethernet card. If your organization's environment does not support 10 Gigabit throughput, the card reduces its speed to 1 Gigabit:

  • 1 Gigabit Connection – Plug in a CAT5e cable for 1 Gigabit throughput.

  • 10 Gigabit Connection – Plug in a CAT6e cable and a 10 Gigabit switch for 10 Gigabit throughput.

Barracuda Message Archiver 950 and 1050 Drive Layout

Model 950 (3U) Drive Layout

bbs_950layout.png
Model 1050 (4U) Drive Layout

bbs_1050layout.png

Barracuda Message Archiver AC Input Voltage Range

Model

AC Input Range

BTU/hr

150

120-230V

737 BTU/hr

350

120-230V

983 BTU/hr

450

120-230V

983 BTU/hr

650

120-230V

1679 BTU/hr

850

120-230V

1679 BTU/hr

950

120-230V

2661 BTU/hr

1050

120-230V

3562 BTU/hr

Barracuda Message Archiver Appliance Wattage/Thermal Output

Model

Input Current
(Amps AC) 

Watts

BTU/hr

150

1.8

216

737 BTU/hr

350

2.4

288

983 BTU/hr

450

2.4

288

983 BTU/hr

650

4.1

492

1679 BTU/hr

850

5.1

612

1679 BTU/hr

950

6.5

780

2661 BTU/hr

1050

8.7

1040

3562 BTU/hr

For more information on calculating the power consumption in watts, see Barracuda Networks Product Power Consumption in Watts.