We use cookies on our website to ensure we provide you with the best experience on our website. By using our website, you agree to the use of cookies for analytics and personalized content.This website uses cookies. More Information
It seems like your browser didn't download the required fonts. Please revise your security settings and try again.
Barracuda CloudGen Firewall

This Firmware Version Is End-Of-Support

Documentation for this product is no longer updated. Please see https://campus.barracuda.com/doc/71862301/ for further information on our EoS policy.

How to Deploy a Barracuda NG Vx using Barracuda NG Install on a VMware Hypervisor

  • Last updated on

The OVA package uses a default configuration that may not be suitable for your deployment. If you want to use multiple network interfaces, a different type of network adapter, or a bigger size for the virtual disk, use Barracuda NG Install to create the custom configuration files that you need to deploy the Barracuda NG Vx with your specific settings.

In this article:

Before You Begin

Step 1. Create Configuration Files with Barracuda NG Install

Create the configuration files with Barracuda NG Install.

  1. Start Barracuda NG Install.
  2. Select the Full wizard mode, and then click Next.
    NGISelectFull.png

  3. On the Box Type Settings page, select the Product Type and Hardware Model for your virtual appliance. You can configure Barracuda NG Virtual Appliances and Barracuda NG Control Centers. After making your selections, click Next.

    NGISelectModel.png

  4. On the Systems Settings page:
    1. Enter the following settings:
      • Hostname – Enter a hostname (e.g., Barracuda NG Firewall VF50).
      • Timezone – Select the timezone that the appliance is in. 
      • Keyboard Layout – Select the keyboard layout for the console of the Barracuda NG Vx.
      • DNS – Enter the DNS servers for your network.
      • Domain Suffix – Enter the domain that your appliance is in.
      • Use NTP & IP – Enable NTP and enter the IP address for the NTP server.
    2. Click Next.
  5. On the Partition Settings page:
    1. In the Fixed Disk Capacity field, enter the virtual disk size in gigabytes. Barracuda Networks recommends that you use disks that are at least the sizes recommended in Firewall Settings.
    2. Click Suggest to adjust the partitions to your disk size.

      NGIDiskSize.png

    3. Click Next.
  6. On the Network Device Settings page:
    1. Select the existing eth0 network card in the Network adapters table and click Delete.
    2. Click Add and then specify these settings in the NIC reseller list window:
      • Reseller – Select VMware.
      • Network adapter – Select vmxnet3 virtual NIC.
      • Number – Select the number of network interfaces.
      NGINumNICs.png
    3. Click OK.
    4. Double-click the eth0 network interface in the Network Adapter table and then specify these settings in the NIC adapter configuration window:
      • Management IP address – Enter the IP address that you want to use as the management IP address.
      • Subnet mask – Enter the subnet mask.
      • (Optional) Configure an Additional Gateway route.
      NGIEnterMIP.png
    5. Click OK
      NGIListNICs.png
    6. Click Next.
  7. On the Security Settings page, enter the Password and Service Login Password and then click Next.
  8. On the Software Packages page, click Next.
  9. On the Script Settings page, enter the destination for your configuration files in the Save to field.
    NGISaveTo.png
  10. Click Next.
  11. Click Finish. After the configuration files are successfully created, a message appears.
    NGIFinished.png
    The following configuration files are created in the destination that you selected:
    NGIConfFiles.png   

Step 2. Create a Floppy Image with WinImage

Add the configuration files that you created with Barracuda NG Install to a floppy image FLP file. You will attach this image to the VMware virtual machine during installation.

  1. Start WinImage.
  2. Locate the configuration files that you created with Barracuda NG Install.
  3. Select all the Barracuda NG Install configuration files and drag them to the WinImage window. 
  4. In the Format selection window, select 1.44 MB from the Standard format list and then click OK.
    WIFormat.png
  5. In the Inject window, click Yes.
    WIInject.png
  6. Click the Save icon.
  7. In the Save as window:
    1. Select Virtual floppy Image (*.vfd,*.flp) from the Save as type list.
    2. Enter a File name with the .flp extension (e.g., NGInstallFloppy.flp). Otherwise, WinImage saves the floppy image with the .vfd extension, which cannot be used by the VMware hypervisor.
      WISaveFile.png
    3. Click Save

Step 3. Create a New Virtual Machine

On the VMware server, create a new virtual machine for the Barracuda NG Vx.

  1. Using VMware vSphere Client, log into your VMware hypervisor.
  2. Right-click the VMware server that you want to deploy the Barracuda NG Vx image on and select New Virtual Machine. The Create New Virtual Machine window opens.
  3. On the Configuration page, select Typical and then click Next.
    VMConfigurationTypical.png
  4. On the Name and Location page, enter a Name for the virtual machine (e.g., BarracudaNGFirewallVF50) and then click Next.
    VMEnterName.png
  5. On the Storage page, select the datastore where the virtual disk should be created and then click Next.
  6. On the Guest Operating System page:
    1. From the Guest Operating System list, select Linux.
    2. From the Version list, select Other 2.6.x Linux (64-bit).
    3. Click Next.
    VMSelectOS.png
  7. On the Network page:
    1. Select the number of network interfaces from the How many NICs do you wan to connect list. The number must match the number of network interfaces that you selected in Step 1. Create Configuration Files with Barracuda NG Install.

      You can only add four network interfaces in the Create New Virtual Machine wizard. If you need more than four virtual network interfaces, add the additional NICs by editing the finished virtual machine configuration. VMware limits the number of virtual network interfaces per guest OS to 10.
    2. For every NIC, specify these settings:
      • Network – Select the virtual network that the virtual interface will connect to. 
      • Adapter – Select VMXNET 3. The adapter must match the Barracuda NG Install configuration. Barracuda Networks recommends using the VMXNET3 driver.
      • Connect at Power On – Select this check box to connect the NIC to the VM.
    3. Click Next
      VMConfigNICs.png
  8. On the Create a Disk page:
    1. Enter the Virtual disk size. For more information, see Firewall Settings.
    2. Select Thick Provision Eager Zeroed.
    3. Click Next. 

    VMDatastore.png

  9. On the Ready to Complete page, click Finish. Depending on your virtual disk size, it can take a couple of minutes for the VM to be created. You can view the status of the Create Virtual Machine task in the Recent Tasks pane at the bottom of the vSphere Client window. 
  10. Right-click the VM that you created and then select Edit Settings.
  11. In the Virtual Machine Properties window:
    1. Configure the Memory and CPUs according to your Barracuda NG Vx model.

      Do not assign more than the licensed number of vCPUs to your virtual machine. For more information, see Licensing.
    2. Click OK.

Your virtual machine is now listed in the left pane under the VMware server that you created it on.

VMListguestOSes.png

Step 4. Power On the Barracuda NG Vx Virtual Machine

Connect the Barracuda NG Vx ISO and the floppy image to the virtual machine for the automated installation.

  1. Using VMware vSphere Client, log into your VMware hypervisor.
  2. Power on your Barracuda NG Vx virtual machine.
  3. From the taskbar, click the CD icon (VMCdromIcon.png), click CD/DVD Drive 1, and then select Connect to ISO image on local disk.
  4. Select the Barracuda NG Vx ISO file on the local hard disk and then click Open.
    VMSelectISO.png
  5. Press Ctrl + Alt + Ins to reboot the VM. 
  6. At the Welcome to Barracuda NG Firewall boot prompt, press any key except to stop the 10 second timeout.
    VMBootPrompt.png
  7. From the taskbar, click the Floppy icon (VMFloppyIcon.png) and select Connect to floppy image on local disk.
  8. From your local hard disk, select the floppy image (e.g., NGInstallFloppy.flp) that you created in Step 2. Create a Floppy Image with WinImage.
    VMSelectFLP.png

  9. Press Enter to start the installation.
  10. After the installation completes, press Enter to reboot. 

VMReboot.png

Next Step

After you deploy the Barracuda NextGen F-Series Vx unit, continue with Getting Started and optionally Best Practice - Performance Tuning on VMware Hypervisors.

Last updated on